Home » Product » Temperature Controller – CD66 1/16 DIN

Temperature Controller - CD66 1/16 DIN

CD Automation’s CD66 is a 1/16 DIN (48 x 48mm) advanced PID temperature controller with two analogue inputs and a multitude of output options.

  • Universal Inputs 1 & 2
  • Math Function (Sum, Difference & Average)
  • Heat/Cool PID Control
  • Ramp/dwell/cooling/timers
  • Relay/SSR drive and DC linear control outputs
  • 3 Independent Alarms
  • RS485 Modbus Comms

SKU: CD66

Temperature Controller - CD66 1/16 DIN

Overview.

The CD66 PID Controller offers all the advanced features you expect from a modern temperature controller, including a high-performance display for excellent readability.

Available with dual analogue input, the CD66 allows you to manage two processes with separate control loops or perform mathematical operations between them, such as sum, difference, or average.

The controller supports multiple output options, including command mode, various alarm modes, and analog retransmission of process or setpoint values.

For network communication, the controller uses an RS485 serial connection with the Modbus-RTU protocol. The versatile power supply, with 24Vac or dc and 115/230Vac versions, add flexibility and ensures stable performance even during power fluctuations.

CD66 RS485 Comms Capability

CD66 RS485 Comms Capability

Key Benefits

  • Sophisticated control ability for heating and cooling applications plus auto/manual control & tuning
  • Soft start feature allows a slow ramp up to setpoint value
  • Dual inputs provide math function control (Sum, Difference & Average between 2 inputs)
  • Pre-programmed profile with ramp, dwell and cooling
  • An intuitive display provides clear values of set & actual temperature, control and alarm status
  • Ability to externally switch between 2 to 4 setpoints, to enable/disable tuning, auto/manual mode and timer run/stop
  • Timer flexibility (2 functions can be set independently, sequentially or looped together)
  • Connect seamlessly with your management software via RS485 Comms

Feature Highlights

  • Heat only, Cool only or Heat & Cool PID control
  • 2 Analogue inputs user configurable for thermocouple, PT100 or DC Linear (mA or V)
  • 2 Control Outputs (Relay, SSR drive or DC Linear (mA or V)
  • Up to 3 Relay Ouputs
  • 4 Digital Inputs/Outputs
  • Remote Setpoint
  • Heater Break Alarm
  • RS485 Modbus Comms

Further Information

Product NameTemperature Controller - CD66
Ideal ForDesigned for all thermal heating and/or cooling applications that require front panel-mounted controls
Voltage Power Supply24Vac or dc (Standard) or 115/230Vac as option (±15%) 50/60Hz
Power Consumption6 Watt/VA
Display4 Digits (0.5"), 5 Digits (0.3")
Primary Input2 x analogue 16bit, programmable for thermocouples K, S, R, J, T, N, B (automatic compensation of cold junction-25 to 85°C, ±0.2% F.S. ±1 digit F.S.), RTD PT100, PT500, PT1000, Ni100, PTC1K, NTC10K (β 3435K), Process signals 0-10 V (50000 points), 0/4-20mA (40000 points), 0-60 mV (25000 points), potentiometer 1-150 KΩ (50000 points)
Digital Inputs4x PNP(overlapped to outputs SSR)
Digital outputs2x SSR 12/24Vdc - 25 mA max overlapped to inputs)
Auxiliary Outputs12/24Vdc - 30mA max for sensor supply
Relay Output3x 2A - 250Vac resistive load
Analogue outputs2x Selection 4-20 mA (40000 points ± 0.2% F.S.) or 0-10Vdc (40000 points ± 0.2% F.S.) for command or retransmission PV/SPV
Serial communicationRS485 (1200 to 115200 Baud) galvanically isolated
Control algorithmsON - OFF with hysteresis, P., P.I., P.I.D., P.D. time proportional
TuningManual or automatic
Alarm modeAbsolute / Threshold, Band, High / Low deviation. Alarm with optional Manual reset. Loop Break Alarm
Dual P.I.D.Heating / Cooling with dual P.I.D.
Soft-StartRising gradient expressed as Degrees / Hour or fixed output percentage
Programmer functionCycle with up to 12 steps and end-of-step recovery/waiting functions

Manuals

  • Currently Unavailable Online
Our Address
Unit 9 Harvington Business Park, Brampton Rd, Eastbourne, BN22 9BN, UK
Need Help?
We aim to reply to email enquiries within 20 minutes (during normal working hours).
Logo CDA_R_Bianco
Opening Hours
CD Automation UK Limited © Copyright 2026. All Rights Reserved.

🎉 Thank you! Your download is ready.

You can access your PDF now by clicking the link below:
Inside, you’ll discover the 5 common mistakes that can affect machine performance and how to avoid them to save time, reduce downtime, and improve product quality.