Solid State Relay - REVO-S 1PH 690V-120A

£1.00
Part Number:
REVO-S 1PH 690V-120A

Simplicity coupled with great function, the real benefits include:

Cost Effective, so the budget doesn't compromise performance.
Precision Power Control, with fast and complex firing types.
Space Saving Design, making panel space no longer an issue.
Clean Electricity, as no interference is produced when switching at zero volts.
Lower Maintenance Costs, with increased heater element lifespan.
Built to Last, with an expected lifespan of over 10 years. 

Firing Range
Zero Cross (SC), Burst Firing (BF)
Communication
None
Option
Heater Break Alarm
Ideal For
Normal Resistance, Medium & Long Wave Infrared load types
  • Resistance Load: Normal Resistance
  • Current Range: 30A, 40A, 60A, 90A, 120A, 150A, 180A, 210A, 280A, 400A, 500A, 600A, 700A
  • Supply Voltage: 24Vac, 480Vac or 600Vac
  • Input Signal: SSR, 0:10Vdc, 4:20mA
  • Firing Types: Zero Cross or Bust Firing (4, 8 or 16 cycles selectable)
  • Options: Heater Break Alarm - To notify you about load failures
  • Protection: IP20, complies with CE & cUL specification
  • Extras: Internal Quick Blow Fuses, Specialised Heat Sink Design
More Information
Product Name Solid State Relay - REVO-S 1PH 690V-120A
Firing Range Zero Cross (SC), Burst Firing (BF)
Input Signal

DC logic (SSR), 4-20mA, 0-10Vdc

Communication None
Feedback Type Open loop
Option Heater Break Alarm
Ideal For Normal Resistance, Medium & Long Wave Infrared load types
Approvals cUL and CE + EMC approved
Altitude Over 1000m of altitude reduce the nominal current of 2% for each 100m.
Auxiliary Voltage Supply

90:130Vac 8VA Max
170:265Vac 8VA Max (Standard)
230:345Vac 8VA Max
300:530Vac 8VA Max (Standard)
510:690Vac 8VA Max

Controlled Phases 1
Heater Break Alarm To diagnose partial or total load failure with automatic setup, relay alarm output and LED indication, available as an option
Humidity From 5 to 95% but without condensation or surface ice
Mounting Screw mounting
Load Type Single Phase (Phase to Phase or Phase to Neutral)
Panel Sealing IP20
Storage Temperature -25 °C to 50 °C Max
Voltage Power Supply 480V, 600V and 690Vac
Voltage Frequency Automatically from 47 to 70 Hz

CD Automation Cares

Every product sold at CD Automation benefits our local and global environment. We believe the more you give in life, the more you will receive. Each one of us are grateful to be able to pay-it-forward and share our platform to help causes bigger than all of us.

giving

discover