Thyristor Power Controller - Multidrive 3PH

£1.00
Part Number:
Multidrive 3PH

Universal thyristor power controller suitable for all 3 phase 3 & 4 wire, resistance and transformer load types. Now superseded by REVO-C 3PH power controller range.

Firing Range
Zero Cross (ZC), Burst Firing (BF), Single Cycle (SC), Phase Angle (PA), Soft Start (SS), Delayed Triggering (DT)
Communication
RS485 Modbus as standard, Profibus DP, Profinet, Ethernet IP as option
Option
Current Limit, Soft Start, Re-transmission Signal, Heater Break Alarm as standard
Ideal For
All load types

Available in 21 Amp sizes from 35A to 2700A the Multidrive provides the user with optimum control of the process and ease of set-up & maintenance.

The Front panel keypad & display allows total flexibility for the user with full configuration of the process & digital inputs types and firing & control modes, to suit the application. Real time values such as the Voltage, Current & Power can be read from the display.

Internal quick-blow fuses as standard provide complete protection for the thyristor. Additional features such as current limit, profiling, heater break alarm and RS485 comms come as standard.

More Information
Product Name Thyristor Power Controller - Multidrive 3PH
Current Range All Others 35A, 45A, 75A, 100A, 125A, 150A, 225A, 300A, 350A, 400A, 450A, 500A, 850A, 1100A, 1400A, 1600A, 1800A, 2100A
Software

Thyristor Configurator

Thyristor Configurator Software. Version V5.7.0.2. 23.7MB download file size.

Firing Range Zero Cross (ZC), Burst Firing (BF), Single Cycle (SC), Phase Angle (PA), Soft Start (SS), Delayed Triggering (DT)
Input Signal

DC logic (SSR), 4-20mA, 0-10Vdc, 10K Pot, RS485 Comms

Communication RS485 Modbus as standard, Profibus DP, Profinet, Ethernet IP as option
Feedback Type Voltage (V), Power (VxI), Current (I), External
Option Current Limit, Soft Start, Re-transmission Signal, Heater Break Alarm as standard
Ideal For All load types
Approvals CE + EMC approved
Altitude Over 1000m of altitude reduce the nominal current of 2% for each 100m
Auxiliary Voltage Supply

90:130Vac 8VA Max
190:256Vac 8VA Max (Standard)

Controlled Phases 3
Heater Break Alarm To diagnose partial or total load failure with automatic setup, relay alarm output and LED indication, available as an option
Humidity From 5 to 95% but without condensation or the effects of ice
Mounting Screw mounting
Load Type 3 Phase (3 or 4 wire)
Panel Sealing IP20
Storage Temperature -25 °C to 50 °C Max
Voltage Power Supply From 24V to 480V (Std) or 600V & 690V as option
Voltage Frequency Automatically from 47 to 70 Hz