1 PHASE Selection Guide |
|
|
|
| ||||
---|---|---|---|---|---|---|---|
Load & Connection Type | No of Units | Controlled Phases | RS1 | RM1 | RCL | RD1 | |
Single Phase, Normal Resistance Load |
Normal resistance, medium and long wave infrared | 1 | 1 | ![]() |
![]() |
![]() |
|
Quartz lamp infrared short waveform | 1 | 1 | ![]() |
![]() |
![]() |
||
Single Phase, Variable Resistance Load |
Variable resistance, Molibdenum, Tungstenum, Superkanthal, Platinum | 1 | 1 | ![]() |
![]() |
||
Silicon Carbide elements | 1 | 1 | ![]() |
![]() |
![]() |
||
Single Phase, Inductive / Transformer Load |
Transformer load coupled with normal resistance | 1 | 1 | ![]() |
![]() |
||
Transformer load coupled with cold resistances (kanthal super) | 1 | 1 | ![]() |
![]() |
|||
3 Phase, Star or Delta load without Neutral |
Normal resistance | 1 | 2 | ||||
3 Phase, Star or Delta load with Neutral |
Normal resistance | 1 | 3 | ||||
3 Phase, Variable Resistance |
Silicon Carbide elements | 1 | 3 | ||||
Molibdenum, Tungstenum, Superkanthal, Platinum, Quartz lamp infrared short waveform | 1 | 3 | |||||
3 Phase, Inductive / Transformer Load |
Three Phase transformer | 1 | 3 | ||||
3 Phase, Normal Resistance, Open Delta |
Three Phase normal load resistance with open delta connection | 1 | 3 | ||||
Cold resistance | 3 | 3 | ![]() |
![]() |
|||
Current Range | 30 to 700A | 30 to 700A | 35 to 700A | 850 to 2700A | |||
Maximum Operating Voltage | 480Vac | ![]() |
![]() |
![]() |
![]() |
||
600Vac | ![]() |
![]() |
![]() |
![]() |
|||
690Vac | ![]() |
![]() |
![]() |
||||
Input Type | SSR 4-30VDC | ![]() |
![]() |
![]() |
|||
4-20mA | ![]() |
![]() |
![]() |
![]() |
|||
0-10V DC | ![]() |
![]() |
![]() |
![]() |
|||
Potentiometer (10K) | ![]() |
![]() |
![]() |
||||
Communication Command | ![]() |
![]() |
![]() |
||||
Firing Type | Zero Crossing | ![]() |
![]() |
||||
Single Cycle | ![]() |
![]() |
|||||
Burst Firing | ![]() |
![]() |
![]() |
||||
Soft Start & Burst Firing | ![]() |
![]() |
|||||
Phase Angle | ![]() |
![]() |
![]() |
||||
Soft Start & Phase Angle | ![]() |
![]() |
![]() |
||||
Delayed Triggering + Burst Firing | ![]() |
![]() |
![]() |
||||
Control Mode | Voltage | ![]() |
![]() |
![]() |
|||
Voltage Square | ![]() |
![]() |
![]() |
||||
Current | ![]() |
![]() |
![]() |
||||
Voltage x Current (Power) | ![]() |
![]() |
![]() |
||||
Voltage to Power Transfer | ![]() |
![]() |
![]() |
||||
External Control Mode | ![]() |
||||||
Options | Internal Current Limit | ![]() |
![]() |
||||
Heater Break Alarm / SCR Short Circuit | ![]() |
![]() |
![]() |
![]() |
|||
Internal Fixed Fuse | ![]() |
![]() |
![]() |
![]() |
|||
Internal Fuse & Holder | |||||||
Flat Wiring Terminal | ![]() |
![]() |
|||||
Communications | RS485 with MODBUS Protocol | ![]() |
![]() |
![]() |
|||
PROFIBUS DP, CAN Open Ethernet | ![]() |
![]() |
![]() |
||||
Front Keypad & Display | ![]() |
![]() |
![]() |
||||
PC Programmable + USB | ![]() |
![]() |
![]() |
||||
REVO Easy | ![]() |
![]() |
![]() |
- Standard
- Optional